1 Controlling the JBL Professional DSC260 System Controller Using SIA-Smaart Pro SIA Software Company, Inc. An EAW Company The SIA-Smaart Pro Real-Time module can control crossover and delay functions on the DSC260 as well as output EQ, limiter, gain and phase compensation. This document discusses details of the Real-Time module s external device control interface specific to the DSC260. More general information about controlling external devices from Smaart Pro can be found in the SIA-Smaart Pro user s manual or the Real-Time Module help file.

Jun 29, 2014 - Bluetooth Trading-usb bluetooth Dongle Easy USB 0 Serial when fix Driver; files. EAW SMAART 6 FREE Technologies Html. Live Sound Analyzer. SmaartTools for iOS single channel RTA is a full-featured audio spectrum analyzer based on the single-channel. Smaart Tools was developed by Studio Six Digital in collaboration with Rational Acoustics and is based.

Preparing a DSC260 for Remote Control The first step in preparing a DSC260 system controller for remote control using SIA-Smaart Pro is to check the version number of the firmware (device-specific software stored in nonvolatile memory) currently running on the unit you want to control. The firmware version shipped with most DCS260s currently in the field does not support external control of this device and will need to be updated. The DSC260, the firmware version, actually consisting of two separate numbers, appears briefly on the front panel display during boot-up. Left right left tv serial song download free.

When you first power the unit up, you should see something like this: JBL DSC-260 B0.12 A1.01 The number beginning with B is the boot version. The number beginning with A is the application version the field-updatable software. Make a note of both numbers.

If the application number is 1.05b or later, the DSC260 is ready for remote control and you can skip ahead to Making control connections on page 2. If the application number is earlier than 1.05b, you will need to update the firmware. Updating the Firmware To update the firmware in the DSC260, you will need the following three items: 1. An RS-232 serial null modem cable. RS-232 is the serial communication standard used in virtually all Windows/IBM compatible computers. A null modem cable is a special type serial cable with the terminal ready and modem ready lines crossed so that the port is held open at all times when two devices are connected.

The DSC260 s serial input (labeled RS232) requires a 9-pin female D connector. The serial (COM) port on your computer, could be a 9- or 25-pin, male or female D connector (only 9 of the pins in a 25-pin serial port are actually used).

You should be able to purchase the cable and/or adapters you need from virtually any computer store. The 'Flash' loader application, 626loadr.exe, used to load the new firmware program into the DSC260's nonvolatile memory 3. The new firmware file for the DSC260 The Flash loader program and updated firmware file for the DSC260 are available for download from the JBL Professional web site ( or the downloads section of the SIA Software Company, Inc. 2 Controlling the JBL Professional DSC260 System Controller Using SIA-Smaart Pro revision 1, 8/99 Page 2 Once you have obtained the necessary software and cable, follow the steps below to upload the new program to the DSC260. Step 1: Connect the DSC260 to your computer. Connect the serial port (labeled RS232) on the rear panel of the DSC260 to a serial (COM) port on your computer using the null modem cable.

If the Boot version number (the number beginning with B displayed on the DSC260 s front panel display on power up) is B0.13 or later you can skip to Step 2 below. If the Boot software is B0.12 or earlier then you will have to disconnect the DSC260 s power cable and reconnect it while holding down the Recall and Mute4 keys. The unit will step through an led test pattern on power up then display a message similar to: OK Check:D993 The DSC260 is now waiting for the PC software to run. Step 2: Uploading the new program. Double-click on the file 626loadr.exe to start the flash loader application. If the path and file name for the new firmware file (626v105b.a21 or later) is not already entered in the Transfer File field, click the Browse button, select the file you want to upload and click OK. Now select the number of the computer s serial port you connected to the DSC260 in the From Comm Port field, select the All option in the To MIDI Channel field, and click the Go button.

The DSC260 will display the message Running Loader. And the loader program will indicate the progress of the file transfer by displaying the percentage sent as the file is uploaded. The DSC260 will restart when the transfer is completed and display the following message: JBL DSC 260 B0.1x Updated The DSC260 should now be enabled for remote control through MIDI or serial connection (using the null modem cable) from Smaart Pro. You will need to configure an External Device definition and select the proper serial port or MIDI channel in the Real-Time module as you would any other supported external device. Note: Depending on how you have Windows file display options set on your computer, 626loadr.hlp and 626loadr.exe may both appear as just '626loadr' in file folder windows.